Powercom

Powercom

Solar-Log™ terminal strip connector

Inverter terminal strip

Terminal

PIN

► 1

► R+

► 1

► T+

► 4

► R-

► 4

► T-

4. Close the inverter if no other inverters are to be connected.

5. Insert the terminal block connector into the Solar-Log™ RS485 socket.

Connect the inverters to each other

Connect using a 4 wire, shielded data cable

Where to connect: Terminal strip inside the inverter on the retrofitted RS485 interface card

Procedure

1.

Open the inverter as shown in the inverter's instructions.

2. Connect terminals R+, T+, R- and R+ of inverter 1 to the corresponding terminals on inverter 2.

3. Connect the other inverters to each other in the same way.

4. Close inverters.