Solare Datensysteme Solar-Log User Manual

Page 288

Advertising
background image

288

Varta Engion Battery System

Varta Engion Battery System

Connect the consumption meter to the Solar-Log™�

The wiring is done using a

RS485 or

S0 interface.

Assigning IP addresses

A static IP address has to be assigned to the battery system.

Please select an IP address with the same class C subnet as the Solar-Log™.
For example: The Solar-Log™ has the IP address 192.168.178.49.
The battery system in this case has to have a free IP address in the same range (from 192.168.178.1
to 192.168.178.254).

Procedure: Start according to the battery system‘s instructions.

Detection via the Solar-Log

WEB interface

For the device detection on the Solar-Log

select „Varta“ in the

Network

section from the

Confi-

guration | Devices | Definition

menu.

Also select the proper interfaces for the meters as well as the inverters. Confirm the selection by
clicking on

Save

.

Detection from the Solar-Log 1200

When using the Solar-Log 1200, the detection can also be started from the display.

Select „Varta“ from the „Network“ interface for the detection.

Also select the proper interfaces for the meters as well as the inverters and then start the detec-
tion.