232

SOCOMEC

SOCOMEC Sunsys B12/B30

77�2 SOCOMEC Sunsys B12/B30

Easy Installation

Termination

Addressing

Interface

No

Yes

Yes

RS485

Selection available under SOCOMEC

Overview

Integrated interface.

Where to connect: RJ45 sockets inside the inverter

3-pin wiring.

The communication address has to be assigned.

Installation steps

Switch off the inverters and Solar-Log™.

Connect inverters to the Solar-Log™.

Connect the inverters to each other according to the inverter instructions

Communication address according to the inverter‘s instructions.

Address range 1 - 255.

Connect inverters to the Solar-Log™

The wiring is done using a

self-made cable connection with RS485 data cable and terminal block connector.

Procedure

1.

Open the inverter according to the inverter‘s instructions.

2. If you are fabricating the cable yourself, connect the wires as shown in the following diagram.

Solar-Log™ terminal strip connector

RJ45 inverter

Terminal

PIN

► 1 Data+

► 5

► 3 GND

► 7

► 4 Data-

► 4

3. Insert the RJ45 plug into the RJ45 socket on the first inverter.

4. If only one inverter is to be connected, terminate this according to the inverter instructions.

5. Close the inverter if no other inverters are to be connected.

6. Insert the terminal block connector into the Solar-Log™ RS485 socket.

Connect the inverters to each other

Connect using a data cable with an RJ45 plug.

Where to connect: RJ45 sockets in the inverter.