103 zeversolar – Solare Datensysteme Solar-Log User Manual

Page 306

Advertising
background image

306

Zeversolar

Zeversolar

103 Zeversolar

103�1 Zeversolar

Easy Installation

Termination

Addressing

Interface

No

Yes

No

RS422

Overview

Interface integrated.

Where to connect: RJ45 socket on the outside of the inverter

4-pin cable – only on RS485/422 B connection of the Solar-Log™

Communication address does not have to be assigned

Note

The order in which the inverters are displayed in the Solar-Log™ after detection is random.
We strongly recommend that you change the order of the inverters immediately after de-
tection at startup, in the

Configuration/Basis/Inverters

dialog box.

The inverters can be identified using the displayed serial number.

Installation steps

Switch off the inverters and Solar-Log™

Install the RS485 interface in the inverter

Connect inverters to the Solar-Log™

Connect the inverters to each other

Connect inverters to the Solar-Log™

The wiring is done using a

ready-made BRJ1 data cable (optional extra; not supplied)

or

self-made cable connection with RS485 data cable and terminal block connector.

Caution

Risk of damage to the unit!
The Solar-Log™ also has an RJ45 socket, which must never be connected to the RJ45
socket on the inverter.

► ☻

Only connect inverters via the RS485/422 B- or the RS485/422-C-Solar-Log™ inter-

face.

Note

Only connect inverter using the RS485/422 B or the RS485/422-C-interface.