Solare Datensysteme Solar-Log User Manual

Page 22

Advertising
background image

22

ABB

ABB Central Inverters

3�2 ABB Central Inverters

Easy Installation

Termination

Addressing

Interface

No

-

Yes

LAN

Select “ABB-PVS” during the inverter detection

Overview

Interface not integrated; Retrofit components (with the label "RETA-01").

Connected using network cable (patch cable) and Ethernet router or switch

Communication address must be allocated.

Installation steps

Allocate communication address

Connect inverters to the Solar-Log™

Connect the inverters to each other

Allocate communication address

Recommendation: Continuous numbering starting with 1; address range 1 to 254.

Setting: Using the inverter operating display

Procedure: Before connecting to the Ethernet router or switch and allocating the IP address.

Connect inverters and the Solar-Log™�

The wiring is done using a

network cable (patch cable) and the

Ethernet router or switch.

Procedure

1.

Set different unit IDs on each inverter in accordance with the inverter's instructions.

2. Connect the Solar-Log™ and the inverter to the router or switch.

3. Assign an IP address to every inverter. Assign the IP addresses according to the inverter's instructions.

The first three number blocks like the Solar-Log™, e.g.

192.168.178

.49.

The fourth number block: an address that is available, e.g. 192.168.178.50.