Enfinity

Enfinity

24 Enfinity

24�1 Enfinity

Easy Installation

Termination

Addressing

Interface

No

-

Yes

RS422

Overview

Integrated interface

2 RJ11 sockets inside the inverter.

4-pin wiring

Communication address does not have to be assigned.

Installation steps

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™

Connect the inverters to each other

Note

Only connect inverter using the RS485/422 B/C interface.

Connect inverters to the Solar-Log™�

The wiring is done using a

self-made, shielded 4 wire data cable and terminal block connector.

Where to connect: RJ11 socket on the inverter.

Procedure

Open the inverter as shown in the inverter's instructions.

1.

If you are making the cable yourself, connect the wires as shown in the following diagram

Solar-Log™ terminal strip connector

Inverter terminal strip

Terminal

Terminal

► 1

► Pin 3 - RX+

► 4

► Pin 4- RX-

► 5

► Pin 1 - TX+

► 6

► Pin 2 TX-

2. Insert the RJ1plug into any RJ11 socket on inverter 1.

3. Close the inverter if no other inverters are to be connected.

4. Insert the terminal block connector into the Solar-Log™ RS485/422 B socket.