Ingeteam

Ingeteam

42 Ingeteam

42�1 Ingeteam

Easy Installation

Termination

Addressing

Interface

No

Jumper P3

Yes

RS485

Overview

Interface not integrated; Retrofit RS485 interface card.

3-pin wiring

Communication address must be allocated.

Installation steps

Switch off the inverters and Solar-Log™

Install the RS485 interface in the inverter

Connect inverters to the Solar-Log™

Connect the inverters to each other

Allocate communication address

Installing the RS485 interface

In the 8-pin connection socket, insert the appropriate plug (Phoenix plug type: FKCT 2.5/8-ST) with RS485

wiring.

Procedure

► Install the RS485 interface in the inverter in accordance with the interface card installation instructions.

Connect inverters to the Solar-Log™

The wiring is done using a

self-made, shielded 3 wire data cable and terminal block connector.

Procedure

1.

Open the inverter as shown in the inverter's instructions.

2. Pull the free wires through the wire opening in the inverter.

3. If you are making the cable yourself, connect the wires as shown in the following diagram:

Solar-Log™ terminal strip connector

Inverter terminal strip

Terminal

Terminal

► 1

► Pin 1 RS485 A (+)

► 3

► Pin 6 GND

► 4

► Pin 2 RS485 B (-)

4. If only one inverter is to be connected this must be terminated.

Insert jumper JP3 into the RS485 card.

5. Close the inverter if no other inverters are to be connected.

6. Insert the terminal block connector into the Solar-Log™ RS485 socket.