70 santerno, 70�1 santerno – Solare Datensysteme Solar-Log User Manual

Page 197

Advertising
background image

197

Santerno

Santerno

70 Santerno

70�1 Santerno

Easy Installation

Termination

Addressing

Interface

No

Yes

Yes

RS485

Overview

Integrated interface

Where to connect: 9 pin socket on the outside of the housing floor.

2-pin wiring

Communication address must be allocated.

Installation steps

Switch off the inverters and Solar-Log™

Install the RS485 interface in the inverter

Connect inverters to the Solar-Log™

Connect the inverters to each other

Allocate communication address

Connect inverters to the Solar-Log™

The wiring is done using a

ready-made Santerno data cable (optional extra; not supplied)

or

self-made, shielded 2 wire data cable with a 9 pin plug and a terminal block connector.

Procedure

1.

If you are making the cable yourself, connect the wires as shown in the following diagram:

Solar-Log™ terminal strip connector

Inverter terminal strip

Terminal

Terminal

► 1

► 1 (A-Line)

► 4

► 2 (B-Line)

2. Insert the plug into socket A on the inverter.

3. If only one inverter is to be connected this must be terminated.

Connect socket A on the Santerno Solar-Log™ data cable to the plug of the first Santerno inverter data

cable.

4. Insert the terminal block connector into the Solar-Log™ RS485 socket.

Connect the inverters to each other

Santerno inverter data cable (optional extra; not supplied)

Where to connect: 9 pin socket on the outside of the housing floor.