77 socomec – Solare Datensysteme Solar-Log User Manual

Page 230

Advertising
background image

230

SOCOMEC

SOCOMEC Sunsys B20E

77 SOCOMEC

77�1 SOCOMEC Sunsys B20E

Easy Installation

Termination

Addressing

Interface

No

Yes

Yes

RS485

Selection available under SOCOMEC

Overview

Integrated interface.

Where to connect: Terminal strip inside the inverter.

3-pin wiring.

The communication address has to be assigned.

Installation steps

Switch off the inverters and Solar-Log™.

Connect inverters to the Solar-Log™.

Communication address according to the inverter‘s instructions.

Address range 1 - 255.

Terminate the inverter according to the inverter‘s instructions.

Connect inverters to the Solar-Log™

The wiring is done using a

self-made, shielded 5 wire data cable and terminal block connector.

Procedure:

Open the inverter according to the inverter‘s instructions.

Pull the free wires through the wire opening in the inverter.

If you are fabricating the cable yourself, connect the wires as shown in the following diagram.

Solar-Log™ terminal strip connector

Terminal strip inverter

Terminal

PIN

► 1 Data+

3

► 1 Data+

5

► 3 GND

2

► 4 Data-

4

► 4 Data-

6

If only one inverter is to be connected terminate this in accordance with the inverter instructions.

Close the inverter if no other inverters are to be connected.

Insert the terminal block connector into the Solar-Log™ RS485 socket.