Procedure

1.

Open the inverter as shown in the inverter's instructions.

2. If you are making the cable yourself, connect the wires as shown in the following diagram:

Solar-Log™ terminal strip connector

Terminal strip inside the inverter

Terminal

RS485 terminal

► 1

► A-Data +

► 4

► B-Data -

3. Connect terminals A and B on inverter 1 to the corresponding terminals on inverter 2.

4. Connect the other inverters to each other in the same way.

5. Terminate the inverter as shown in the inverter's instructions.

6. Close inverters.

7. Insert the terminal block connector into the Solar-Log™ RS485 socket.

Allocate communication address

Recommendation: Continuous numbering starting with 1.

Setting: Using the solar fitter's menu on the inverter.

Procedure: Start according to the inverter's instructions