Vision

Vision Singletracker

97�2 Vision Singletracker

Easy Installation

Termination

Addressing

Interface

No

DIP switch

Yes

RS485

Select “Vision SM” during the inverter detection

Overview

Integrated interface

3-pin wiring

2 RJ45 sockets on the outside of the inverter.

Communication address must be allocated.

Installation steps

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™

Connect the inverters to each other

Allocate communication address.

Address range 1 to 254

Settings on the inverter’s display according to the manufacturer’s manual.


Connect inverters to the Solar-Log™

The wiring is done using a

self-made cable connection with RS485 data cable and terminal block connector.

Caution

Risk of damage to the unit!
The Solar-Log™ also has an RJ45 socket, which must never be connected to the RJ45
socket on the inverter.

Only connect inverters via the RS485/422 Solar-Log™ interface(s).