260

Sungrow

Sungrow

84 Sungrow

84�1 Sungrow

Easy Installation

Termination

Addressing

Interface

Yes

120

Ω resistor

Yes

RS485

Overview

Integrated interface

Where to connect: RJ45 socket or COM round sockets on the outside of the inverter

2-pin wiring

Communication address must be allocated.

Installation steps

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™

Connect the inverters to each other

Allocate communication address

Note:

The inverter's communication connection is then changed to the from the round socket to
RJ45. Currently, the SG1,5KTL is still supplied with round sockets.

Connect inverters to the Solar-Log™

The wiring is done using a

self-made, shielded 2 wire data cable with round plug and terminal block connector.

Procedure

1.

If you are making the cable yourself, connect the wires as shown in the following diagram:

Solar-Log™ terminal strip connector

Round socket inverter for SG1,5KTL

Terminal

PIN

► 1

► 1 (A)

► 4

► 2 (B)