55 pairan – Solare Datensysteme Solar-Log User Manual

Page 161

Advertising
background image

161

Pairan

Pairan

55 Pairan

55�1 Pairan

Easy Installation

Termination

Addressing

Interface

No

Jumper

No

RS485

Overview

Integrated interface

Where to connect: Round socket on inverter

2-pin wiring

Communication address does not have to be assigned.

Installation steps

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™

Connect the inverters to each other

Connect inverters to the Solar-Log™

The wiring is done using a

self-made cable connection with the round plug and the terminal strip plug.
The round plug must be obtained from the manufacturer.

Procedure

1.

If you are making the cable yourself, connect the wires as shown in the following diagram

View of the connection socket

Figure 15: Pairan Round socket

Solar-Log™ terminal strip connector

Inverters

RS485/422 B

Round socket

► 1

► Data +

► 4

► Data -

2. Insert the terminal block connector into the Solar-Log™ RS485 socket.