Solare Datensysteme Solar-Log User Manual

Page 266

Advertising
background image

266

Sunpower

Sunpower SPR-M-Model connect with original SMA RS485 piggy back and the SMARS485 data module

85�3 Sunpower SPR-M-Model connect with original SMA RS485 piggy back

and the SMARS485 data module

Easy Installation

Termination

Addressing

Interface

Yes

Resistor jumper

No

RS485

Select “SMA” during the inverter detection

Overview

Interface not integrated; retrofit the SMA RS485 piggyback card

Where to connect: Terminal strip inside the inverter on the piggyback

Communication address does not have to be assigned

3-pin wiring

Installation steps

Switch off the inverters and Solar-Log™

Installing the original SMA RS485 piggyback in the inverter

Connect inverters to the Solar-Log™

Connect the inverters to each other

Installing the original SMA RS485 piggyback in the inverter

Procedure

► Install the original SMA RS485 piggy back in the inverter in accordance with the interface card installa-

tion instructions.

Connect inverters to the Solar-Log™

The wiring is done using a

ready-made data cable (optional extra; not supplied)

or

self-made, shielded 3 wire data cable and terminal block connector.

Procedure

1.

Open the inverter as shown in the inverter‘s instructions.

2. Pull the free wires through the wire opening in the inverter.

3. Pull the cable through the insulation tube.

Note

The wire must be enclosed in the insulating hose inside the inverter.

4. If you are making the cable yourself, connect the wires as shown in the following diagram:

Advertising