100 würth – Solare Datensysteme Solar-Log User Manual

Page 299

Advertising
background image

299

Würth

Würth SolarStar-Series

100 Würth

100�1 Würth SolarStar-Series

Easy Installation

Termination

Addressing

Interface

Yes

No

Yes

RS485

Select “SolarMax” during the inverter detection

Supported Models:

SolarStar a2000

SolarStar a3000

SolarStar a4200

SolarStar a6000

Overview

Integrated interface

Where to connect: RJ45 socket on the outside of the inverter

6-pin wiring

Communication address must be allocated.

Installation steps

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™

Connect the inverters to each other

Allocate communication address

Connect inverters to the Solar-Log™

The wiring is done using a

self-made RS485 data cable with RJ45 plug and terminal block connector.

Caution

Risk of damage to the unit!
The Solar-Log™ also has an RJ45 socket, which must never be connected to the RJ45
socket on the inverter.

Only connect inverters via the RS485/422 Solar-Log™ interface(s).