4�2 advanced energy - ae-3 – Solare Datensysteme Solar-Log User Manual

Page 27

Advertising
background image

27

Advanced Energy

Advanced Energy - AE-3

4�2 Advanced Energy - AE-3

Easy Installation

Termination

Addressing

Interface

Yes

Terminating plug

Yes

RS485

Select “Refusol” during the inverter detection

Overview

Integrated interface

Where to connect: RJ45 socket on the bottom of the inverter

2-pin wiring

Communication address must be allocated.

Installation steps

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™

Connect the inverters to each other

Allocate communication address

Connect inverters to the Solar-Log™

The wiring is done using a

self-made, shielded 2 wire data cable and terminal block connector.

Procedure

1.

Connect wires as shown in the diagram below.

Solar-Log™ terminal strip connector

RS485 inverter socket

Terminal

PIN

► 1

► 2

► 4

► 3

2. If only one inverter is to be connected this must be terminated.

On the sockets „RS485 OUT“ with REFUSOL round plugs bypass the connections PIN1 to PIN2 and

PIN3 to PIN4.

3. Close the inverter if no other inverters are to be connected.

4. Insert the terminal block connector into the Solar-Log™ RS485 socket.

Connect the inverters to each other

Connect using
– 2-wire, shielded data cable and
– 4-pin „SACC-M12MS-4SC“ plug (two plugs included with the inverter)

Where to connect: RS485 sockets on the bottom of the inverter.

The RS485 IN and OUT sockets are each double connections so that the wiring can be continued to the

next inverter.

Procedure

1.

Connect the data cable to the „SACC-M12MS-4SC“ plug as shown in the inverter‘s instructions.

2. Insert one plug into the OUT (X14B) socket of inverter 1.

3. Insert the other end of the wire into the IN socket (X15B) on inverter 2.

4. Connect the other inverters to each other in the same way.

5. Terminate in the last inverter.