Shindengen

Procedure

1.

Open the inverter as shown in the inverter’s instructions.

2. If you are fabricating the cable yourself, connect the wires as shown in the following diagram.

Terminal strip inside the inverter

Terminal strip inside the inverter

RS485 terminal

RS485 terminal

► 30 A (+)

► 30 A (+)

► 31 GND

► 31 GND

► 13 B (-)

► 13 B (-)

3. Connect terminals on inverter 1 to the corresponding terminals on inverter 2.

4. Connect the other inverters to each other in the same way.

5. If only one inverter is to be connected, terminate it according to the inverter instructions.

6. Close inverters.

7. Insert the terminal block connector into the Solar-Log™ RS485 socket.

Allocate communication address

Recommendation: Continuous numbering from 1 to 30

Procedure: Start according to the inverter’s instructions.