51 motech – Solare Datensysteme Solar-Log User Manual

Page 153

Advertising
background image

153

Motech

Motech (RS485)

51 Motech

51�1 Motech (RS485)

Easy Installation

Termination

Addressing

Interface

No

Yes

No

RS485

Overview

Integrated interface

Where to connect: RJ45 plug outside the housing floor

2-pin wiring

Communication address does not have to be assigned

Installation steps

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™

Connect the inverters to each other

Connect inverters to the Solar-Log™

The wiring is done using a

ready-made BRJ2 data cable (optional extra; not supplied)

or

self-made cable connection with RS485 data cable and terminal block connector.

Caution

Risk of damage to the unit!
The Solar-Log™ also has an RJ45 socket, which must never be connected to the RJ45
socket on the inverter.

Only connect inverters via the RS485/422 Solar-Log™ interface(s).

Procedure

1.

If you are making the cable yourself, connect the wires as shown in the following diagram:

Solar-Log™ terminal strip connector

RJ45 inverter

Terminal

PIN

► 1

► 7

► 4

► 8

2. Insert the RJ45 plug into the RJ45 socket on the inverter.

3. If only one inverter is to be connected terminate this in accordance with the inverter instructions.

4. Insert the terminal block connector into the Solar-Log™ RS485 socket.