91 tbea, 91�1 tbea – Solare Datensysteme Solar-Log User Manual

Page 279

Advertising
background image

279

TBEA

TBEA

91 TBEA

91�1 TBEA

Easy Installation

Termination

Addressing

Interface

No

120

Ω resistor

Yes

RS485

Overview

Integrated interface

Where to connect: Round sockets on the outside of the inverter.

2-pin wiring

The communication address has to be assigned.

Installation steps

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™

Connect the inverters to each other

Assign the communication address; address range 1 to 247

Connect inverters to the Solar-Log™

self-made, shielded 2 wire data cable with round plug and terminal block connector.

Procedure

1.

If you are fabricating the cable yourself, connect the wires as shown in the following diagram.

Solar-Log™ terminal strip connector

Inverter round socket

Terminal

PIN

► 1

► 1

► 4

► 3

2. Insert the round plug into the COM round socket 1 on the inverter.

3. If only one inverter is to be connected terminate this in accordance with the inverter instructions.

4. Insert the terminal block connector into the Solar-Log™ RS485 socket.

Connect the inverters to each other

Connect using a data cable with a round plug

Where to connect: Round sockets on the outside of the inverter.