13 carlo gavazzi – Solare Datensysteme Solar-Log User Manual

Page 54

Advertising
background image

54

Carlo Gavazzi

Carlo Gavazzi - ISMG model

13 Carlo Gavazzi

13�1 Carlo Gavazzi - ISMG model

Easy Installation

Termination

Addressing

Interface

No

-

No

RS485

Select "Gavazzi ISMG" during the inverter detection.

Overview

Integrated interface

Where to connect: RJ45 socket on the outside of the inverter

2-pin wiring

Communication address does not have to be assigned.

Connect inverters to the Solar-Log™

The wiring is done using a

ready-made BRJ2 data cable (optional extra; not supplied)

or

self-made, shielded 2 wire data cable and terminal block connector.

Installation steps

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™

Connect the inverters to each other

Caution

Risk of damage to the unit!
The Solar-Log™ also has an RJ45 socket, which must never be connected to the RJ45
socket on the inverter.

Only connect inverters via the RS485/422 Solar-Log™ interface(s).

Procedure

1.

If you are making the cable yourself, connect the wires as shown in the following diagram

Solar-Log™ terminal strip connector

Inverters

RS485/422 B

RJ 45 socket

► 1

► Pin 7

► 4

► Pin 8

2. Insert the RJ45 plug into any RJ45 socket on inverter 1.

3. Insert the terminal block connector into the Solar-Log™ RS485 socket.

Advertising