247

SolaX Power

SolaX Power X3

Connect the inverters to each other

Connect using a RJ45 cable.

Where to connect: RJ45 socket.

Procedure

1.

Insert the self-made cable with the RJ45 plug into any RJ45 socket on inverter 1. Connect the other

end to the terminal plug on the Solar-Log™.

2. Insert the RJ45 cable into the 2nd RJ45 socket on inverter 1 and into any RJ45 socket on

inverter 2.

3. Connect the other inverters to each other in the same way.

4. Insert the terminal block connector into the Solar-Log™ RS485 socket.

5. Terminate in the last inverter in accordance with the inverter instructions.

Allocate communication address

1.

Recommendation: Continuous numbering starting with 1.
Address range 1 - 247.

2. Setting: Using the inverter operating display.
3. Procedure: Start according to the inverter's instructions.