16 conergy – Solare Datensysteme Solar-Log User Manual

Page 66

Advertising
background image

66

Conergy

Conergy (only Solar-Log 1000 and 2000)

16 Conergy

16�1 Conergy (only Solar-Log 1000 and 2000)

Note

Conergy inverters can only be connected to the Solar-Log 1000 and 2000, as only this one
has a CAN interface.

The following description relates to inverters without transformers produced in or after 2007.

Easy Installation

Termination

Addressing

Interface

No

Yes

No

CAN bus

Overview

CAN only to be used on Solar-Log 1000 and 2000 (CAN interface).

Integrated interface

Where to connect: CAN socket on the outside of the bottom of the inverter.

Only use ready-made cable sets.
Two different special cable sets must be ordered separately.

-

Prefabricated cable set between the Solar-Log 1000 and 2000 and the first inverter, including

cable termination.

-

Ready-made cable set with 5 pin Phoenix contact connection plug for connecting the inverters to

each other.

-

Depending on the number of inverters several of these cables will be required.

Maximum total cable length: 200 m

Communication address does not have to be assigned

Installation steps

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™

Connect the inverters to each other

Connect the inverters to the Solar-Log 1000 and 2000�

Connection is only done using a ready-made data cable, specially for connecting to the Solar-Log 1000

and 2000 (optional extra; not supplied).

Procedure

1.

Insert the CAN plug into the inverter CAN IN socket.

2. If only one inverter is to be connected this must be terminated.

Insert the two 5 pin 120

Ω terminal resistors from the ready-made cable set into the CAN OUT socket.

3. Insert the terminal block connector into the Solar-Log 1000 and 2000 CAN socket.