10 aten – Solare Datensysteme Solar-Log User Manual

Page 48

Advertising
background image

48

Aten

Aten

10 Aten

10�1 Aten

Easy Installation

Termination

Addressing

Interface

No

-

No

RS485

Overview

Integrated interface

Where to connect: RJ14 socket on the outside of the inverter.

2-pin wiring

Communication address does not have to be assigned.

Installation steps

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™

Connect the inverters to each other

Connect inverters to the Solar-Log™

The wiring is done using a

self-made, shielded 2 wire data cable and terminal block connector

.

Procedure

1.

If you are making the cable yourself, connect the wires as shown in the following diagram

Solar-Log™ terminal strip connector

Inverters

RS485/422 B

RJ 14 socket

► 1

► Pin 2 - Data +

► 4

► Pin 4 - Data -

Figure 14: RJ14 socket pin allocation

2. Close the inverter if no other inverters are to be connected.

3. Insert the terminal block connector into the Solar-Log™ RS485 socket.