101 yaskawa, 101�1 yaskawa – Solare Datensysteme Solar-Log User Manual

Page 301

Advertising
background image

301

Yaskawa

Yaskawa

101 Yaskawa

101�1 Yaskawa

Easy Installation

Termination

Addressing

Interface

No

Yes

Yes

RS485

Overview

Integrated interface

Where to connect: Terminal strip inside the inverter

Communication address must be allocated.

3-pin wiring

Installation steps

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™

Address the inverter.

Connect the inverters to each other

Terminate the inverter as shown in the inverter's instructions.

Connect inverters to the Solar-Log™

The wiring is done using a

self-made cable connection with terminal block connector.

Procedure

1.

Open the inverter as shown in the inverter's instructions.

2. Pull the free wires through the wire opening in the inverter.

3. If you are making the cable yourself, connect the wires as shown in the following diagram:

Note

Please note that the connection label (e.g. 2-6) refers to the second row on the terminal
block, connection 6).

Solar-Log™ terminal strip connector

RJ45 inverter

Terminal

PIN

► 1-(Data+) A

2-6 D+

► 3-GND

1-8 GND

► 4-(Data-) B

2-7 D-

4. If only one inverter is to be connected, it must be terminated according to the manufacturer's instruc-

tions.

5. Close the inverter cover if no other inverters are to be connected.

6. Insert the terminal block connector into the Solar-Log™ RS485 socket.