68�2 salicru eqxlv – Solare Datensysteme Solar-Log User Manual

Page 194

Advertising
background image

194

SALICRU

SALICRU EQXLV

68�2 SALICRU EQXLV

Easy Installation

Termination

Addressing

Interface

No

Resistor

Yes

RS485

Overview

Integrated interface

2-pin wiring

Communication address must be allocated.

Installation steps

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™

Connect the inverters to each other

Allocate communication address

Connect inverters to the Solar-Log™

The wiring is done using a

ready-made data cable (optional extra; not supplied)

or

self-made, shielded 2 wire data cable and terminal block connector.

Procedure

1.

If you are making the cable yourself, connect the wires as shown in the following diagram:

Solar-Log™ terminal strip connector

Inverter terminal strip

Terminal

Terminal

► 1

► 4 (A in)

► 4

► 3 (B in)

2. If only one inverter is to be connected this must be terminated.

Insert 120

Ω terminal resistor.

3. Insert the terminal block connector into the Solar-Log™ RS485 socket.

Connect the inverters to each other

Connect using a 2 wire, shielded data cable

Where to connect: Terminal strip inside the inverter

Procedure

1.

Connect terminal 2 (A out) on inverter 1 to terminal 4 (A in) on inverter 2.

2. Connect terminal 1 (B out) on inverter 1 to terminal 3 (B in) on inverter 2.

3. Connect the other inverters to each other in the same way.

4. Terminate in the last inverter. Insert 120

Ω terminal resistor.

Allocate communication address

Recommendation: Continuous numbering starting with 1.

Setting: Using PC software for configuring inverters.

Procedure: Start according to the inverter's instructions