44 klne, 44�1 klne (solartec and sunteams) – Solare Datensysteme Solar-Log User Manual

Page 136

Advertising
background image

136

KLNE

KLNE (Solartec and Sunteams)

44 KLNE

44�1 KLNE (Solartec and Sunteams)

Easy Installation

Termination

Addressing

Interface

No

Yes

Yes

RS485

Overview

Integrated interface

Where to connect: 4-pin round socket on the button of the device

2-pin wiring

Communication address must be allocated.

Installation steps

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™

Connect the inverters to each other

Allocate communication addresses

Connect inverters to the Solar-Log™

The wiring is done using a

self-made cable connection with terminal block connector.

Where to connect: 4-pin round socket on the button of the device

Procedure

1.

If you are making the cable yourself, connect the wires as shown in the following diagram:

Solar-Log™ terminal strip connector

X4 socket inverter

Terminal

PIN

► 1

4 - Data+

► 4

2 - Data-

2. If only one inverter is to be connected, according to the manufacturer's handbook it must be termina-

ted.

3. Insert the terminal block connector into the Solar-Log™ RS485 socket.

Connect the inverters to each other

Where to connect: 4-pin round socket on the button of the device

Procedure

1.

Unscrew the side cover as shown in the inverter's instructions.

2. If you are making the cable yourself, connect the wires as shown in the following diagram: