11 benning – Solare Datensysteme Solar-Log User Manual

Page 50

Advertising
background image

50

Benning

Benning

11 Benning

11�1 Benning

Easy Installation

Termination

Addressing

Interface

No

No

Yes

LAN

Overview

Integrated interface

The inverter's IP address has to be assigned.

Connected using network cable (patch cable) and Ethernet router or switch

Installation steps

The inverter's has to be assigned a static IP address.

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™ (RJ45).

Connect the inverters to each other (RJ45).

Connect inverters to the Solar-Log™

The wiring is done using a

network cable (patch cable/crossover cable) and the

Ethernet router or switch.

Connect the inverters to each other

The inverters are connected together using

the RJ45 interface and, if needed, a router or switch.

Connection setup according to the inverter's instructions.

Assigning IP addresses

A static IP address has to be assigned to the inverter via the display.

Please select an IP address with the same class C subnet as the Solar-Log™.
For example: The Solar-Log™ has the IP address 192.168.178.49.
The inverter in this case has to have a free IP address in the same range (from 192.168.178.1 to
192.168.178.254).

Procedure: Start according to the inverter's instructions

Note

Each inverter has to be individually reachable via the network. For this, the network inter-
face has to be activated for every inverter (select "Activate LAN" under the LAN menu)
and and the inverter needs to be connected to the local access network (LAN) via a switch.

Advertising