80�2 solax power x3 – Solare Datensysteme Solar-Log User Manual

Page 246

Advertising
background image

246

SolaX Power

SolaX Power X3

80�2 SolaX Power X3

Easy Installation

Termination

Addressing

Interface

No

Yes

Yes

RS485

The following types are to be connected according to this diagram:

ZDNY-TL10000, ZDNY-TL12000, ZDNY-TL15000, ZDNY-TL17000

Select SolaXPower X3 during the inverter detection.

Overview

Integrated interface.

2 RJ45 sockets on the outside of the inverter.

2-pin wiring.

Communication address must be allocated.

Installation steps

Switch off the inverters and Solar-Log™.

Connect inverters to the Solar-Log™.

Connect the inverters to each other

Allocate communication address.

Address range 1 to 247

Settings on the inverter's display according to the manufacturer's manual.

Connect inverters to the Solar-Log™�

The wiring is done using a

self-made, shielded 8 wire data cable and terminal block connector.

Where to connect: RJ45 socket on the inverter

Procedure

1.

If you make the cable yourself, connect the wires as shown in the following diagram.

Solar-Log™ terminal strip connector

RS485 inverter socket

Terminal

PIN

► 1

► Pin 4 - Data+

► 4

► Pin 5 - Data-

2. Insert the RJ45 plug into any RJ45 socket on inverter 1.

3. If only one inverter is to be connected, terminate it according to the inverter instructions.

4. Insert the terminal block connector into the Solar-Log™ RS485 socket.