Solare Datensysteme Solar-Log User Manual

Page 185

Advertising
background image

185

REFUSOL

REFUSOL

Set the following parameters on the inverter's operating display:

1.

Press "F1"

2.

Select

Numerical list

, press "ENTER".

3. Set parameter number

0407

press "ENTER"

4. Select sub parameter 0407,3, press "ENTER"

5. Enter "2"

[Communication type RS485: Solarlog], press "ENTER".31], press "ENTER".

6. Set parameter number

0420

press "ENTER"

7. Select sub parameter

0420,3,

press "ENTER"

8. Enter the numerical value

9600,

press "ENTER"

9. Using the installed DC isolating switch turn the inverters on and off briefly so that the settings are

activated.

Note

The numerical value "2" under point 5 in the settings refers to the old Solar-Log protocol
and the value "1" to the native protocol for active and reactive power control.

The value under point 8 refers to the inverter's baud rate and is 9600 for the old Solar-Log pro-

tocol and 57600 for the native protocol.

Allocate communication address

Recommendation: Continuous numbering starting with 1.

Setting: Using the inverter operating display

Procedure: Start according to the inverter's instructions

Note

To use active and reactive power management, all of the inverters need to be set to:

Protocol 1

57600 baud

Parameter 1164 = 2