Solutronic

Solutronic SP100, SP120 (RS485)

Procedure

1.

Insert the plug into the X6 socket on inverter 1.

2. Insert the other end of the wire into the X7 socket on inverter 2.

3. Connect the other inverters to each other in the same way.

4. Terminate in the last inverter according to the manufacturer's instructions.

Allocate communication address

Setting: Using the inverter's control panel, parameter 89 in the communication menu.
Recommendation: Continuous numbering starting with 1.
Set this in the SSP address menu item.

Procedure: Start according to the inverter's instructions

Note

The mode Fixed cos Phi has to be set according to the manufacturer's specifications for all
of the inverters to use active and reactive power management.