14�3 chint power modbus – Solare Datensysteme Solar-Log User Manual

Page 62

Advertising
background image

62

Chint Power

Chint Power Modbus

14�3 Chint Power Modbus

Easy Installation

Termination

Addressing

Interface

No

No

Yes

RS485

The following types are to be connected according to this diagram:

CPS SCA5KTL-DO

CPS SCA6KTL-DO

CPS SCA7KTL-DO

CPS SCA8KTL-DO

CPS SCA10KTL-DO

CPS SCA12KTL-DO

CPS SCA8KTL-DO/HE

CPS SCA10KTL-DO/HE

CPS SCA12KTL-DO/HE

Select the inverter Chint-Mod for the inverter detection.

Overview

Integrated interface

Where to connect: RJ45 socket on the outside of the inverter

2-pin wiring

The communication addresses (1-247) have to be assigned

Installation steps

Switch off the inverters and Solar-Log™

Connect inverters to the Solar-Log™

Connect the inverters to each other

Allocate communication address

Caution

Risk of damage to the unit!
The Solar-Log™ also has an RJ45 socket, which must never be connected to the RJ45
socket on the inverter.

Only connect inverters via the RS485/422 Solar-Log™ interface(s).

Connect inverters to the Solar-Log™

The wiring is done using a

self-made, shielded 2 wire data cable with a RJ45 socket and a terminal block connector.