67�1 Riello

Easy Installation

Termination

Addressing

Interface

No

Yes

No

RS422

Overview

Interface not integrated; Retrofit RS485 interface card.

4-pin cable – only on RS485/422 B connection of the Solar-Log™

Communication address does not have to be assigned.

Multi-string technology

Riello inverters are fitted with 1 or 3 MPP trackers depending on the model. Each string input is monitored

separately and ideally adjusted to the connected modules.

The Solar-Log™ automatically detects how many inverters and strings are active during inverter detection.

Note

The order in which the inverters are displayed in the Solar-Log™ after detection is random.
We strongly recommend that you change the order of the inverters immediately after de-
tection at startup, in the

Configuration/Basis/Inverters

dialog box.

The inverters can be identified using the displayed serial number.

Installation steps

Switch off the inverters and Solar-Log™

Install the RS485 interface in the inverter

Connect inverters to the Solar-Log™

Connect the inverters to each other

Installing the RS485 interface
Procedure

► Insert the RS485 interface in the bottom of the inverter in accordance with the interface card installati-

on instructions and screw in.

Connect inverters to the Solar-Log™

The wiring is done using a

ready-made data cable (optional extra; not supplied)

or

self-made, shielded 4 wire data cable and terminal block connector.

Note

Only connect inverter using the

RS485/422 B

/C interface.