80 solax power – Solare Datensysteme Solar-Log User Manual

Page 244

Advertising
background image

244

SolaX Power

SolaX Power X1

80 SolaX Power

80�1 SolaX Power X1

Easy Installation

Termination

Addressing

Interface

No

Yes

Automatic

RS422

The following types are to be connected according to this diagram:

SL-TL1500, SL-TL2200, SL-TL2500, SL-TL2800, SL-TL3000, SL-TL3300T, SL-TL3600T, SL-TL4400T,

SL-TL5000T

Select SolaXPower X1 during the inverter detection.

Overview

Integrated interface.

2 RJ45 sockets on the outside of the inverter.

4-pin wiring.

Communication address does not have to be assigned

Installation steps

Switch off the inverters and Solar-Log™.

Connect inverters to the Solar-Log™.

Connect the inverters to each other

Note

Only connect inverter using the RS485/422 B or RS485/422 C interface.

Connect inverters to the Solar-Log™�

The wiring is done using a

self-made, shielded 8 wire data cable and terminal block connector.

Where to connect: RJ45 socket on the inverter

Caution

Risk of damage to the unit!
The Solar-Log™ also has an RJ45 socket, which must never be connected to the RJ45
socket on the inverter.

Only connect inverters via the RS485/422 Solar-Log™ interface(s).