1 parameterisation dialog/signal flow, Parameterisation dialog/signal flow, 5motor control (mctrl) – Lenze E84DSxxx User Manual
Page 115

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
115
5
Motor control (MCTRL)
5.4
V/f characteristic control (VFCplus)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.4.1
Parameterisation dialog/signal flow
Proceed as follows to open the dialog for parameterising the motor control:
1. »Engineer« Go to the Project view and select the 8400 protec StateLine controller.
2. Select the Application parameters tab from the Workspace.
3. Select the motor control from the Overview dialog level in the Motor control list field:
• "6: VFCplus: V/f linear" for linear characteristic or
• "8: VFCplus: V/f quadr" for square-law characteristic
Alternatively also the motor control "10: VFCplus: V/f definable" can be selected. In the
case of this motor control the V/f characteristic can be defined freely.
4. Click the Motor control V/f button to change to the Overview Motor control V/f dialog
box.
• This dialog level only shows a simplified signal flow with the most important
parameters.
• When you click the >>More details button in the left-most position, a signal flow with
more details/parameters is displayed.