This chapter lists all parameters of the operating system in numerically ascending order.

C00002

Note!

The parameter descriptions are based on software version V07.00.00.

Parameter | Name:

C00002 | Device command

Data type: UNSIGNED_8

Index: 24573

d

= 5FFD

h

Note:

• Before switching off the supply voltage after a device command has been executed, check the successful

execution of the device command via the status display in

C00003

!

• Before activating device commands by a master control, wait for the "Ready" signal of the controller.

• The device will reject a write process to C00002/x if the value is >1 and issue an error message.

Drive control (DCTRL)

:

Device commands

Selection list

0 Off / ready
1 On / start
4 Action cancelled
5 No access
6 No access controller inhibit

20 20% working
40 40% working
60 60% working
80 80% working

Subcodes

Lenze setting

Info

C00002/1

0: Off / ready

Load Lenze setting

• All parameters are reset to the Lenze setting.

• Only possible when the controller is inhibited.

C00002/2

0: Off / ready

Reserved

C00002/3

0: Off / ready

Reserved

C00002/4

0: Off / ready

Reserved

C00002/5

0: Off / ready

Reserved

C00002/6

0: Off / ready

Load all parameter sets

• All parameter sets are loaded by the memory module.

• Only possible when the controller is inhibited.

C00002/7

0: Off / ready

Reserved

C00002/8

0: Off / ready

Reserved

C00002/9

0: Off / ready

Reserved

C00002/10

0: Off / ready

Reserved

C00002/11

0: Off / ready

Save all parameter sets

• All parameter sets are saved to the memory module

safe against mains failure.

C00002/12

0: Off / ready

Reserved

C00002/13

0: Off / ready

Reserved

Advertising