C01094
C01095
C01120
Parameter | Name:
C01094 - LS_ParReadWrite 1-3: Numerator
Data type: INTEGER_16
Index: 23481
d
= 5BB9
h
From version 06.00.00
: Factor (numerator) for internal conversion in arithmetic modes 1 ... 3.
Setting range
(min. value | unit | max. value)
-32767
32767
Subcodes
Lenze setting
Info
C01094/1
1
: Numerator
C01094/2
1
: Numerator
C01094/3
1
: Numerator
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01095 - LS_ParReadWrite 1-3: Denominator
Data type: INTEGER_16
Index: 23480
d
= 5BB8
h
From version 06.00.00
: Factor (denominator) for internal conversion in arithmetic modes 1 ... 3.
Setting range
(min. value | unit | max. value)
1
32767
Subcodes
Lenze setting
Info
C01095/1
1
: Denominator
C01095/2
1
: Denominator
C01095/3
1
: Denominator
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01120 | Sync signal source
Data type: UNSIGNED_8
Index: 23455
d
= 5B9F
h
Selection of the signal source for device synchronisation
• The drive can only be synchronised by one source.
Selection list
(Lenze setting printed in bold)
Info
0 Off
Synchronisation off
1 CAN on board
Synchronisation via "CAN on board" system bus
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1