C00567 | resp. to speed controller limited, C00569 | resp. to peak current, C00570 | resp. to controller limitations – Lenze E84DSxxx User Manual
Page 562: C00570/4, C00570/1, C00570/2, C00570/3, C00569/1, C00567, 15 parameter reference

15
Parameter reference
15.2
Parameter list | C00567
562
Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00567
C00569
C00570
Parameter | Name:
C00567 | Resp. to speed controller limited
Data type: UNSIGNED_8
Index: 24008
d
= 5DC8
h
Response if speed controller output is limited (bLimSpeedCtrlOut = TRUE)
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00569 | Resp. to peak current
Data type: UNSIGNED_8
Index: 24006
d
= 5DC6
h
Configuration of monitoring of the motor control (group 1)
Selection list
0 No Reaction
1 Fault
5 Warning
Subcodes
Lenze setting
Info
C00569/1
0: No Reaction
Response for overcurrent detection and clamp operation
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00570 | Resp. to controller limitations
Data type: UNSIGNED_8
Index: 24005
d
= 5DC5
h
Configuration of monitoring of the motor control (group 2)
Selection list
0 No Reaction
1 Fault
5 Warning
Subcodes
Lenze setting
Info
C00570/1
0: No Reaction
Response if direct-axis current controller is limited
C00570/2
0: No Reaction
Response if cross current controller is limited
C00570/3
0: No Reaction
Response if torque setpoint is limited
• Limitation of the speed controller output, the
differential setpoint feedforward control, and the
additive torque at sensorless vector control (
C00570/4
0: No Reaction
Response if field controller is limited
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1