C00505 | password data, C00507 | current password protection, C00505/3 – Lenze E84DSxxx User Manual
Page 559: C00507/1, C00505/2, Ding binding id in, C00505/1, 15 parameter reference

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
559
15
Parameter reference
15.2
Parameter list | C00505
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00505
C00507
C00516
Parameter | Name:
C00505 | Password data
Data type: VISIBLE_STRING
Index: 24070
d
= 5E06
h
From version 06.00.00
Subcodes
Lenze setting
Info
C00505/1
MasterPin
C00505/2
Binding ID
C00505/3
Password
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00507 | Current password protection
Data type: UNSIGNED_16
Index: 24068
d
= 5E04
h
From version 06.00.00
Display of the currently active device access protection
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 Only access to user menu
Bit 1 Parameter write protection
Bit 2 Parameter read protection
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Memory module binding on
Subcodes
Info
C00507/1
Password protection - all communication channels
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00516 | Checksums
Data type: UNSIGNED_32
Index: 24059
d
= 5DFB
h
This code is for device-internal use only and must not be written to by the user!