C00685

C00686

C00687

C00696

C00697

Parameter | Name:

C00685 | L_Compare_2: Fct.

Data type: UNSIGNED_8

Index: 23890

d

= 5D52

h

The

L_Compare_2

FB: Comparison operation

• If the statement of the selected comparison operation is true, the binary bOut output will be set to TRUE.

Selection list

(Lenze setting printed in bold)

1 In1 = In2
2 In1 > In2
3 In1 < In2
4 |In1| = |In2|
5 |In1| > |In2|
6 |In1| < |In2|

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00686 | L_Compare_2: Hysteresis

Data type: INTEGER_16

Index: 23889

d

= 5D51

h

The

L_Compare_2

FB: Hysteresis for the comparison function selected in

C00685

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

100.00 0.50 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00687 | L_Compare_2: Window

Data type: INTEGER_16

Index: 23888

d

= 5D50

h

The

L_Compare_2

FB: Window for the comparison function selected in

C00685

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

100.00 2.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00696 | L_OffsetGainP_1: Offset

Data type: INTEGER_16

Index: 23879

d

= 5D47

h

The

L_OffsetGainP_1

FB: Offset (additive to the input signal)

Setting range

(min. value | unit | max. value)

Lenze setting

-199.99

%

199.99 0.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00697 | L_OffsetGainP_2: Offset

Data type: INTEGER_16

Index: 23878

d

= 5D46

h

The

L_OffsetGainP_2

FB: Offset (additive to the input signal)

Setting range

(min. value | unit | max. value)

Lenze setting

-199.99

%

199.99 0.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100