C00685 | l_compare_2: fct, C00686 | l_compare_2: hysteresis, C00687 | l_compare_2: window – Lenze E84DSxxx User Manual
Page 582: C00696 | l_offsetgainp_1: offset, C00697 | l_offsetgainp_2: offset, C00696, C00697, Can be set in, 15 parameter reference

15
Parameter reference
15.2
Parameter list | C00685
582
Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00685
C00686
C00687
C00696
C00697
Parameter | Name:
C00685 | L_Compare_2: Fct.
Data type: UNSIGNED_8
Index: 23890
d
= 5D52
h
FB: Comparison operation
• If the statement of the selected comparison operation is true, the binary bOut output will be set to TRUE.
Selection list
(Lenze setting printed in bold)
1 In1 = In2
2 In1 > In2
3 In1 < In2
4 |In1| = |In2|
5 |In1| > |In2|
6 |In1| < |In2|
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00686 | L_Compare_2: Hysteresis
Data type: INTEGER_16
Index: 23889
d
= 5D51
h
FB: Hysteresis for the comparison function selected in
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
100.00 0.50 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00687 | L_Compare_2: Window
Data type: INTEGER_16
Index: 23888
d
= 5D50
h
FB: Window for the comparison function selected in
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
100.00 2.00 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00696 | L_OffsetGainP_1: Offset
Data type: INTEGER_16
Index: 23879
d
= 5D47
h
FB: Offset (additive to the input signal)
Setting range
(min. value | unit | max. value)
Lenze setting
-199.99
%
199.99 0.00 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00697 | L_OffsetGainP_2: Offset
Data type: INTEGER_16
Index: 23878
d
= 5D46
h
FB: Offset (additive to the input signal)
Setting range
(min. value | unit | max. value)
Lenze setting
-199.99
%
199.99 0.00 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100