C00720 | l_digitaldelay_1: delay, C00720/1, C00720/2 – Lenze E84DSxxx User Manual
Page 587: 15 parameter reference

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
587
15
Parameter reference
15.2
Parameter list | C00705
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00705
C00706
C00720
C00701/45
0: Not connected
: bFreeIn5
(input for binary user signal 5)
C00701/46
0: Not connected
: bFreeIn6
(input for binary user signal 6)
C00701/47
0: Not connected
: bFreeIn7
(input for binary user signal 7)
C00701/48
0: Not connected
: bFreeIn8
(input for binary user signal 8)
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00701 | LA_NCtrl: Digital connection list
Data type: UNSIGNED_16
Index: 23874
d
= 5D42
h
Parameter | Name:
C00705 | LA_NCtrl_Out: Analog signal list
Data type: UNSIGNED_16
Index: 23870
d
= 5D3E
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00706 | LA_NCtrl_Out: Digital signal list
Data type: UNSIGNED_16
Index: 23869
d
= 5D3D
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00720 | L_DigitalDelay_1: Delay
Data type: UNSIGNED_32
Index: 23855
d
= 5D2F
h
Switch-on/off delay time
Setting range
(min. value | unit | max. value)
0.000
s
3600.000
Subcodes
Lenze setting
Info
C00720/1
0.000 s
: ON delay
C00720/2
0.000 s
: OFF delay
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000