C00148 | config. group error, C00148, The short16 – Lenze E84DSxxx User Manual
Page 502: Is activated in, 15 parameter reference

15
Parameter reference
15.2
Parameter list | C00148
502
Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00148
Parameter | Name:
C00148 | Config. group error
Data type: UNSIGNED_16
Index: 24427
d
= 5F6B
h
From version 02.00.00
Selection of the device statuses for which the bCollectedFail group error output of SB
is to be set
to TRUE.
Setting range
(min. hex value | max. hex value)
Lenze setting
0x0000
0xFFFF 0x0030 (decimal: 48)
Value is bit-coded: ( = bit set)
Info
Bit 0 SafeTorqueOff
Bit 1 ReadyToSwitchOn
Bit 2 SwitchedOn
Bit 3 TroubleQSP
From version 06.00.00
Bit 4 Trouble
Bit 5 Fault
Bit 6 Warning
Bit 7 ImpIsActive
Bit 8 CInhIsActive
Bit 9 Fail CAN_Management
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Use 16BitFailNo.
From version 06.00.00
If this bit is set, the short 16-bit error number
(wStateDetermFailNoShort) is also provided at the
wStateDetermFailNoLow output of the
SB
.
• In this case, the wStateDetermFailNoHigh output is
"0".
• Advantage: The bus transfer of the error numbers is
possible via a data word without changing the
interconnection of the technology application.
Read access Write access CINH PLC STOP No transfer COM MOT