2 jog setpoints, 3 setpoint inversion, 4 value range of the input signal – Lenze E84DSxxx User Manual
Page 753: Jog setpoints, Setpoint inversion, Value range of the input signal, 17 function library

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
753
17
Function library
17.1
Function blocks | L_NSet_1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.26.2 JOG setpoints
In addition to the direct main setpoint selection via the nNSet_a input, so-called JOG setpoints can
be preset in
.
• The JOG setpoints are binary-coded and can be called using the bJog1 ... bJog8 selection inputs
so that 15 options are available:
• The number of selection inputs to be assigned depends on the number of JOG setpoints
required:
17.1.26.3 Setpoint inversion
The output signal of the JOG function is led via an inverter.
The sign of the setpoint changes if bNSetInv is set to TRUE.
17.1.26.4 Value range of the input signal
The value range of the input signal can be limited by using the following parameters:
•
: MaxLimit (default setting: +199.99 %)
•
: MinLimit (default setting: -199.99 %)
Selection inputs
Main setpoint
Main setpoint
bJog8
bJog4
bJog2
bJog1
FALSE
FALSE
FALSE
FALSE
nNset_a
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
TRUE
FALSE
FALSE
FALSE
TRUE
TRUE
FALSE
TRUE
FALSE
FALSE
FALSE
TRUE
FALSE
TRUE
FALSE
TRUE
TRUE
FALSE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
FALSE
TRUE
FALSE
FALSE
TRUE
TRUE
FALSE
TRUE
FALSE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
FALSE
TRUE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
FALSE
TRUE
TRUE
TRUE
TRUE
Number of JOG setpoints required
Number of selection inputs to be assigned (bJog1 ... bJog8)
1
At least 1
2 ... 3
at least 2
4 ... 7
at least 3
8 ... 15
4