C00420 | number of encoder increments, C00423 | dox: delay times, C00425 | encoder scanning time – Lenze E84DSxxx User Manual
Page 545: C00420, C00425, C00420/1, C00425/1, C00423/1, C00423/2, C00423/3

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
545
15
Parameter reference
15.2
Parameter list | C00420
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00420
C00423
C00425
Parameter | Name:
C00420 | Number of encoder increments
Data type: UNSIGNED_16
Index: 24155
d
= 5E5B
h
Indication of the encoder constant
Setting range
(min. value | unit | max. value)
1
Incr./rev.
32768
Subcodes
Lenze setting
Info
C00420/1
128 incr./rev.
Encoder increments at FreqIn12
C00420/2
128 incr./rev.
Number of encoder increments at FreqIn56
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00423 | DOx: Delay times
Data type: UNSIGNED_16
Index: 24152
d
= 5E58
h
Delay times for the digital output terminals
Setting range
(min. value | unit | max. value)
0.000
s
65.000
Subcodes
Lenze setting
Info
C00423/1
0.000 s
DO1 ON delay
C00423/2
0.000 s
DO1 OFF delay
C00423/3
0.000 s
DO2 ON delay
C00423/4
0.000 s
DO2 OFF delay
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C00425 | Encoder scanning time
Data type: UNSIGNED_8
Index: 24150
d
= 5E56
h
Encoder sample time for the digital input terminals when configured as frequency inputs
Using DI1(5) and DI2(6) as frequency inputs
Selection list
0 1 ms
1 2 ms
2 5 ms
3 10 ms
4 20 ms
5 50 ms
6 100 ms
7 200 ms
8 500 ms
9 1000 ms
Subcodes
Lenze setting
Info
C00425/1
3: 10 ms
Encoder sample time FreqIn12
C00425/2
3: 10 ms
Encoder sample time FreqIn56
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1