C01501 | resp. to communication error with mci, C01501/1, C01501/2 – Lenze E84DSxxx User Manual
Page 631: 15 parameter reference

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
631
15
Parameter reference
15.2
Parameter list | C01501
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01501
C01751
C01752
C01755
C01763
C01764
Parameter | Name:
C01501 | Resp. to communication error with MCI
Data type: UNSIGNED_8
Index: 23074
d
= 5A22
h
Configuration of monitoring functions for the communication module
Selection list
0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information
Subcodes
Lenze setting
Info
C01501/1
0: No Reaction
Resp. to MCI connection error
• Response to a communication error of the attached
communication module.
C01501/2
0: No Reaction
Resp. to invalid MCI module
• Response to an unplugged or incompatible
communication module
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01751 | Service code inverter charact.
Data type: UNSIGNED_8
Index: 22824
d
= 5928
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01752 | Service Par. TRC function
Data type: UNSIGNED_8
Index: 22823
d
= 5927
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01755 | Service Par. TRC factor
Data type: INTEGER_16
Index: 22820
d
= 5924
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01763 | Service code - clamp threshold
Data type: INTEGER_16
Index: 22812
d
= 591C
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01764 | Service Par. Clamp time
Data type: UNSIGNED_8
Index: 22811
d
= 591B
h
This code is for device-internal use only and must not be written to by the user!