Parameter list | C00056

486

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00056

C00057

C00058

C00059

C00061

Parameter | Name:

C00056 | Torque

Data type: INTEGER_32

Index: 24519

d

= 5FC7

h

Display of the current torque
Display range

(min. value | unit | max. value)

-65000.00

Nm

65000.00

Subcodes

Info

C00056/1

Torque setpoint

• Only in case of sensorless vector control (

SLVC

).

C00056/2

Actual torque value

• Estimated actual torque for all motor control modes.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00057 | Maximum torque

Data type: UNSIGNED_32

Index: 24518

d

= 5FC6

h

Display of the maximum torque to be generated by the motor

• The maximum torque to be generated by the motor depends on various factors, e.g. on Imax in motor mode

(

C00022

) and the motor type used.

Display range

(min. value | unit | max. value)

0.00

Nm

65000.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00058 | Output frequency

Data type: INTEGER_32

Index: 24517

d

= 5FC5

h

Display of the current output frequency
Display range

(min. value | unit | max. value)

-1300.00

Hz

1300.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00059 | Appl.: Reference frequency C11

Data type: UNSIGNED_32

Index: 24516

d

= 5FC4

h

Display of the field frequency which corresponds to the reference speed set in

C00011

.

Display range

(min. value | unit | max. value)

0.00

Hz

1300.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00061 | Heatsink temperature

Data type: INTEGER_16

Index: 24514

d

= 5FC2

h

Display of the current heatsink temperature
Display range

(min. value | unit | max. value)

-50

°C

150

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1