17 function library – Lenze E84DSxxx User Manual
Page 732

17
Function library
17.1
Function blocks | L_DigitalLogic_1
732
Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameter
Truth table for C00820 = 4
Example: If in case of the signal combination bln1 = FALSE, bln2 = FALSE and bln3 = TRUE, the output
signal bOut is to be = TRUE,
must be set to "TRUE":
Parameter
Possible settings
Info
Function selection
0 "0"
Constant value "FALSE"
1 "1"
Constant value "TRUE"
2
AND operation
3
OR operation
4 bOut = f (truth table)
The output value depends on the
parameterised truth table
see truth table
Truth table
Each of the 8 possible input
combinations can be assigned to the
output value FALSE or TRUE.
bIn3
bIn2
bIn1
Output signal bOut
FALSE
FALSE
FALSE
(FALSE or TRUE)
FALSE
FALSE
TRUE
(FALSE or TRUE)
FALSE
TRUE
FALSE
(FALSE or TRUE)
FALSE
TRUE
TRUE
(FALSE or TRUE)
TRUE
FALSE
FALSE
(FALSE or TRUE)
TRUE
FALSE
TRUE
(FALSE or TRUE)
TRUE
TRUE
FALSE
(FALSE or TRUE)
TRUE
TRUE
TRUE
(FALSE or TRUE)
bIn3
bIn2
bIn1
Output signal bOut
TRUE
FALSE
FALSE
(TRUE)
bOut
bIn1 bIn2 bIn3
∧
∧
=
bOut
bIn1 bIn2 bIn3
∨
∨
=