C00008 | original application|control source, 15 parameter reference – Lenze E84DSxxx User Manual

Page 477

Advertising
background image

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

477

15

Parameter reference

15.2

Parameter list | C00008

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00008

"Switch-off positioning" TA

Input/output

10: Terminals 0

12: Terminals 2

14: Terminals 11

16: Terminals 16

RFR

Controller enable

Controller enable / Reset of error message

DI1

Fixed setpoint 1/3

Stop function 1

Fixed setpoint 1/3

DI2

Fixed setpoint 2/3

Stop function 2

Selection: Pre-switch off 1

Fixed setpoint 2/3

DI3

Reset error message

CW rotation quick stop

Selection: Switch-off position 1

CW rotation quick stop

DI4

Change of direction of

rotation

CCW rotation quick stop

Selection: Switch-off position 2

CCW rotation quick stop

DI5

-

-

Stop function 2

-

DI6

-

-

Selection: Pre-switch off 2

-

A1U

Main speed setpoint (10 V ≡ 100 % reference speed)

Parameter | Name:

C00008 | Original application|control source

Data type: UNSIGNED_16

Index: 24567

d

= 5FF7

h

Display of the originally selected technology application and the originally selected control mode.

• This parameter shows the selection that was set with

C00005

and

C00007

before a change in the I/O level or the

application level was carried out.

• For diagnostic purposes, this display serves to determine whether there is a standard interconnection in the

controller or a change carried out by the user.

Selection list

(read only)

Info

0 Free|Free

Application: Interconnection has been changed.

I/O level: Interconnection has been changed.

10 Free|Terminal0

Application: Interconnection has been changed.

I/O level: "Terminals 0" control mode

12 Free|Terminal2

Application: Interconnection has been changed.

I/O level: "Terminal 2" control mode

14 Free|Terminal11

Application: Interconnection has been changed.

I/O level: "Terminal 11" control mode

16 Free|Terminal 16

Application: Interconnection has been changed.

I/O level: "Terminal 16" control mode

20 Free|Keypad

Application: Interconnection has been changed.

I/O level: "Keypad" control mode

21 Free|PC

Application: Interconnection has been changed.

I/O level: "PC" control mode

30 Free|CAN

Application: Interconnection has been changed.

I/O level: "CAN" control mode

40 Free|MCI

Application: Interconnection has been changed.

I/O level: "MCI" control mode

1000 Speed|Free

Application: Actuating drive speed

I/O level: Interconnection has been changed.

1010 Speed|Terminal0

Application: Actuating drive speed

I/O level: "Terminals 0" control mode

1012 Speed|Terminal2

Application: Actuating drive speed

I/O level: "Terminal 2" control mode

1014 Speed|Terminal11

Application: Actuating drive speed

I/O level: "Terminal 11" control mode

1016 Speed|Terminal16

Application: Actuating drive speed

I/O level: "Terminal 16" control mode