5 activate/deactivate quick stop, Activate/deactivate quick stop, Activate/deactivate quick stop ( 76) – Lenze E84DSxxx User Manual
Page 76: 4device control (dctrl)

4
Device control (DCTRL)
4.1
Device commands (C00002/x)
76
Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.1.5
Activate/deactivate quick stop
The
= "1: On / start" device command activates the quick stop function, i.e. the motor
control is separated from the setpoint selection, and within the deceleration time parameterised
the motor is brought to a standstill (n
act
= 0).
• The motor is kept at a standstill during closed-loop operation.
• A pulse inhibit is set if the auto-DCB function has been activated via
.
The
= "0: Off / ready" device command deactivates the quick stop again, provided that
no other source of a quick stop is active.
•
provides a bit coded representation of all active sources/triggers of a quick stop:
Parameter
Info
Lenze setting
Value Unit
Decel. time - quick stop
2.000 s
Bit Cause/Source of controller inhibit
Bit 0 Reserved
Bit 1 CAN control word (bit 2)
Bit 2 MCI control word (bit 2)
Bit 3 Reserved
Bit 4 Application (
system block: bQspOn input)
Bit 5 Device command (
Bit 6 Device error with "TroubleQSP" error response
Bit 7 Internal signal
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Operating system
Bit 11 Reserved
Bit 12 MCK (System block
: Input bQspOn)
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved