C00177 | switching cycles, C00178 | elapsed-hour meter, C00179 | power-on time meter – Lenze E84DSxxx User Manual

Page 514: C00180 | running time, C00177/1, C00177/2, C00177/3, C00177/4, C00177/5, C00178

Advertising
background image

15

Parameter reference

15.2

Parameter list | C00177

514

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00177

C00178

C00179

C00180

Parameter | Name:

C00177 | Switching cycles

Data type: UNSIGNED_32

Index: 24398

d

= 5F4E

h

Counter of different switching cycles and stressful situations
Display range

(min. value | unit | max. value)

0

2147483647

Subcodes

Info

C00177/1

Number of mains switching cycles

C00177/2

Number of switching cycles of the output relay

C00177/3

Short circuit counter

C00177/4

Earth fault counter

C00177/5

"Clamp" counter

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00178 | Elapsed-hour meter

Data type: UNSIGNED_32

Index: 24397

d

= 5F4D

h

Display of operating hours in seconds
Display range

(min. value | unit | max. value)

0

s

2147483647

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00179 | Power-on time meter

Data type: UNSIGNED_32

Index: 24396

d

= 5F4C

h

Display of the power-on time in seconds
Display range

(min. value | unit | max. value)

0

s

2147483647

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00180 | Running time

Data type: UNSIGNED_32

Index: 24395

d

= 5F4B

h

Display of various running times in seconds
Display range

(min. value | unit | max. value)

0

s

2147483647

Subcodes

Info

C00180/1

Running time - control card

C00180/2

Running time - heatsink fan

C00180/3

Running time - internal fan

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising