38 l_signalmonitor_a, L_signalmonitor_a, 17 function library – Lenze E84DSxxx User Manual

Page 778

Advertising
background image

17

Function library

17.1

Function blocks | L_SignalMonitor_a

778

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.1.38

L_SignalMonitor_a

This FB outputs four analog signals which can be selected from a list of analog output signals of all

function blocks provided in the device.

• Offset and gain of the source signals are adjustable.

Outputs

Parameter

Identifier

Data type

Value/meaning

nOut1_a

INT

Output signal

• Internal limitation to ±32767

nOut2_a

INT

Output signal

• Internal limitation to ±32767

nOut3_a

INT

Output signal

• Internal limitation to ±32767

nOut4_a

INT

Output signal

• Internal limitation to ±32767

Parameter

Possible settings

Info

C00410/1

...

C00410/4

Selection of the signal sources for

nOut1_a ... nOut4_a

0 Not connected

1000 LA_nCtrl_wDriveControlStatus
1001 LA_nCtrl_wFailNumber
1002 LA_nCtrl_nMotorCurrent_a

... ...

42017 LA_nCtrl_In_nPIDSerValue_a

C00413/1

C00413/3

C00413/5

C00413/7

-199.99

%

+199.99 Offset

C00413/2

C00413/4

C00413/6

C00413/8

-199.99

%

+199.99 Gain

/B6LJQDO0RQLWRUBD

Q2XWBD

&

&

&

Q2XWBD

&

&

&

Q2XWBD

&

&

&

Q2XWBD

&

&

&

Advertising