38 l_signalmonitor_a, L_signalmonitor_a, 17 function library – Lenze E84DSxxx User Manual
Page 778

17
Function library
17.1
Function blocks | L_SignalMonitor_a
778
Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.38
L_SignalMonitor_a
This FB outputs four analog signals which can be selected from a list of analog output signals of all
function blocks provided in the device.
• Offset and gain of the source signals are adjustable.
Outputs
Parameter
Identifier
Data type
Value/meaning
nOut1_a
INT
Output signal
• Internal limitation to ±32767
nOut2_a
INT
Output signal
• Internal limitation to ±32767
nOut3_a
INT
Output signal
• Internal limitation to ±32767
nOut4_a
INT
Output signal
• Internal limitation to ±32767
Parameter
Possible settings
Info
...
Selection of the signal sources for
nOut1_a ... nOut4_a
0 Not connected
1000 LA_nCtrl_wDriveControlStatus
1001 LA_nCtrl_wFailNumber
1002 LA_nCtrl_nMotorCurrent_a
... ...
42017 LA_nCtrl_In_nPIDSerValue_a
-199.99
%
+199.99 Offset
-199.99
%
+199.99 Gain
/B6LJQDO0RQLWRUBD
Q2XWBD
&
&
&
Q2XWBD
&
&
&
Q2XWBD
&
&
&
Q2XWBD
&
&
&